Legion Fire-Fighting
 
  Fogex System · Control Valves  
 
 
 
 
Unit Name:
Control Valve
System Name:
Fogex Water Mist System
Model:

Open Control Valves

XSW-FZ 15/16K
XSW-FZ 20/16K
XSW-FZ 25/16K
XSW-FZ 32/16K
XSW-FZ 40/16K
XSW-FZ 50/16K

Closed Control Valves

XSW-FZ 15/16B
XSW-FZ 20/16B
XSW-FZ 25/16B
XSW-FZ 32/16B
XSW-FZ 40/16B
XSW-FZ 50/16B

Brief Introduction:
Control valves include open zoned and closed zoned valves. Open zoned control valves have a variety of starting methods.
 
Open Zoned Control Valves Detailed Parameters
Model Nominal Diameter Maximum Pressure/Mpa Size(mm) Working Voltage Working Current Switching Time(S) Ball Valve Manufacturer Manufacturer
XSW-FZ 15/16K 15 16 550×220×750 DC24V 0.8A 10 GEKO PHIREX
XSW-FZ 20/16K 20 16
XSW-FZ 25/16K 25 16
XSW-FZ 32/16K 32 16 580×240×900
XSW-FZ 40/16K 40 16
XSW-FZ 50/16K 50 16

*Open Control Valves Start-up Mode

  • Remote start: Central control center or fire alarm control panel sends a start signal to the partition control valve. The partition control valve should be able to open normally.
  • Manual start: The junction box on the control valve has buttons to control the opening and closing of the electric ball valve. After connecting the line, manually press the green open button, the electric ball valve/electric stop valve can be opened; manually press the red close button, the electric ball valve/electric valve can be closed.
  • Mechanical start: If there is a circuit failure, you need to use the handle to start the control valve. On the bottom or side of the electric actuator of the electric ball valve/electric stop valve, there is a rotary shaft. Turn the rotary shaft with a special wrench to open or close the electric ball valve/electric valve.
Closed Zoned Control Valves Detailed Parameters
Model Nominal Diameter Maximum Pressure/Mpa Size(mm) Flow Switch Manufacturer
XSW-FZ 15/16B 15 16 550×240×750 BANNA PHIREX
XSW-FZ 20/16B 20 16
XSW-FZ 25/16B 25 16
XSW-FZ 32/16B 32 16
XSW-FZ 40/16B 40 16
XSW-FZ 50/16B 50 16

*Closed Control Valves Start-up Mode

Closed control valves are generally installed before each corresponding zone. When a fire breaks out, the glass ball breaks down and the flow switch feedbacks the signal. The main pump is activated by the central control center or the fire alarm control panel. The high pressure water can enter the protected area and discharge the fine water mist through the closed partition control valve.

 
Pump Units We have electric high-pressure reciprocating piston pumps and diesel high-pressure reciprocating piston pumps. Pneumatically driven pumps are also available on request. View More
Nozzles The water mist nozzle consists of two types: open and closed, which have the characteristics of direct spray, strong penetration, high redundancy and high reliability. View More
Control
Valves
Control valves include open zoned and closed zoned valves. Open zoned control valves have a variety of starting methods. View More
System
Accessories
The water mist system accessory includes water tanks, exhaust valves, and an Internet of Things inspection system. View More
 
 
 
 
Technical Support
We have long-term and stable cooperation with higher technical talents in many universities in China. They provide us with a steady stream of fresh blood and more technological innovations.
 
Quality Assurance
Our Fogex water mist fire extinguishing system have obtained many product certifications such as FM, ABS, CE, LR, BV and DNV.
 
After-sale Warranty
We have excellent sales and after-sales service teams in various provinces and cities in China to provide customers with excellent after-sales services.
 
Service Guarantee
We provide a 7×24-hour hotline and promptly provide product consulting services.